The LogTag® UTREL30-16 DUAL is a 30 day logger with display, the recommended vaccine monitoring logger. This Temperature Recorder measures and stores up to 30,000 temperature readings (16,000 per channel) in a measuring range from -90 °C to +40 °C via the external sensor. Enough for 67 days at 6 minute logging.
The display is designed to show ‘at a glance’ if temperature excursions have occurred during the current day and up to the previous 30 days. The display also shows the current temperature reading, the current time, recording status and battery status.
The alarm is triggered if temperature readings are outside pre-set alarm limits. The status indicator changes from a ✔ to a X,the red LED is flashing and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option.
Details of any excursion in the preceding 30 days can be checked directly by inspecting the statistics history on the recorder’s display or in more detail by downloading the logged data via a micro-USB cable to LogTag® Analyzer operating software.
Product Model |
UTREL30-16 |
External Temperature Sensor Measurement Range |
-90 °C to +40 °C (-130 °F to +104 °F) |
Recorder Operating Temperature Range |
-30 °C to +60 °C (-22 °F to +140 °F). 0 – 99 % RH (non-condensing) |
Storage Temperature Range |
0 °C to +40 °C (32 °F to +104 °F) |
Rated Temperature Reading Accuracy |
Better than ±0.5 °C for -20 °C to +10 °C (-4 °F to 50 °F) Better than ±0.7 °C for -50 °C to -20 °C (-58 °F to -4 °F) and +10 °C to +30 °C (50 °F to 86 °F) Better than ±1 °C for -80 °C to -50 °C (-112 °F to -58 °F ) and +30 °C to +40 °C (86 °F to 104 °F) Better than ±1.8 °C for -90 °C to -80 °C (-130 °F to -112 °F) |
Rated Temperature Reading Resolution |
Better than 0.1 °C (0.2 °F) for measurements -80 °C to 10 °C (-112 °F to 50 °F) Better than 0.2 °C (0.4 °F) for measurements 10 °C to 20 °C (50 °F to 68 °F) and -90 °C to -80 °C (-130 °F to -112 °F) Better than 0.3 °C (0.5 °F) for measurements 20 °C to 30 °C (68 °F to 86 °F) Better than 0.5 °C (0.9 °F) for measurements 30 °C to 40 °C (86 °F to 104 °F) LogTag Analyzer currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag |
Sensor Reaction Time |
Typically less than 2 minutes(T90) in moving air (1m/s) for ST10S type probe. |
Recording Capacity |
32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics |
Sampling Interval |
Configurable from 30 seconds to 18 hours. (Typically 5 minute logging) |
Logging Start Options |
Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time |
Alarms |
Up to 6 individually configurable alarms for each channel. Possible to set alarms separately for Channel 1 and Channel 2 |
Download Time |
Typically with full memory (32,000 readings) in less than 20 seconds |
Environmental |
IP61 (when vertically mounted or hung with USB dust-cap in place) |
Power source |
5V via micro USB socket or 2 x 1.5V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only) |
Battery Life |
AAA battery up to 12 months - if unit is operated without power supply |
Real Time Clock |
Built-in real time clock. Typical accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C) |
Connection Interface |
USB 2.0 / Micro USB Socket |
Standard Remote Sensor Cable Length |
Standard: 1.5m (4’11”). Extended: 3m (9’10”) (recommended maximum) |
Remote Sensor Cable Type |
PTFE (FDA food contact rated) coaxial |
Size |
141 mm(H) x 72 mm(W) x 18 mm(T) |
Weight |
156 g with AAA batteries, (132g - excluding probe and AAA batteries) |
Case Material |
Polycarbonate |
Probe Connectivity |
Up to 2 |
Probe Compatibility |
All ST10 precision thermistor external probes can be interchangeably connected to the UTREL30-16. Please refer to the Accessories section for compatible External Probes. Different probe models can be used for each channel. Not compatible with ST100 sensors |
Wall Mount Bracket WMB-02
For loggers UTRED30 and UTREL30
Glycol Buffer
The LogTag® Glycol Buffer is used where the temperature of (...)
External Probes and Smart Probes
All external probes and smart probes at a glance